2. Commissioning

2.1.2 Address assignment of the CPX terminal

2-8
Basic rules for addressing
Inputs and outputs
The address assignment of the inputs does not depend on
the outputs.
The counting mode is independent of the position of the
bus node.
Counting from left to right.
The setting for the number of valves on the pneumatic
interface of 1 and 3 bytes is always rounded up to the full
word (2 or 4 bytes).
Sequence:
For diagnostics mode 2:
32 diagnostic bits in front of the input bits.
Input/output words of the analogue modules,
Input/output words of the function modules (word-
orientated),
Input/output bits of the electric inputs and outputs
(including valves):
For diagnostics mode 3:
16 diagnostic bits followed by the input bits from the
next word.
For diagnostics mode 4:
32 diagnostic bits followed by the input bits from the
next word.
Festo P.BE-CPX-FB20/21-EN en 1202a