1. Installation
1-18
Connecting
Proceed as follows:
1. Break through the sealing rubber with a screwdriver.
2. Place the Quickon screw, the clamping box and the seal-
ing rubber on the polymer fibre cable. The sealing rubber
must be flush with the edge of the insulation (see Fig. 1/6,
diagram A).
3. Push both black cores through the splice ring. The
smooth side of the splice ring must face towards the
cable.
Note
– Note the marking IN/OUT on the splice ring.
– Cross the individual cores on the opposite splice ring
(see Fig. 1/6, Pos. 5 ).
– If you have inserted the individual cores incorrectly in
the splice ring, you must not turn the cores, as they will
then be damaged.
4. Push both black cores through the appropriate opening in
the Rugged Line plug until they project at the other end
(see Fig. 1/6, diagram B).
Festo P.BE-CPX-FB20/21-EN en 1202a