3. Diagnostics and error handling
M (Modify) – Parameterisation modified or forcing active
LED (yellow)
Procedure
ON
OFF
LED is off
ON
OFF
LED
illuminates
ON
OFF
LED flashes
1)
The display of the Force function (LED flashes) has precedence over the display of the setting for
System start (LED lights up).
Festo P.BE-CPX-FB20/21-EN en 1202a
Status
System start with default
parameterisation (factory
setting) and current CPX
equipment status is set;
external parameterisation
is possible (pre-setting).
System start with saved
parameterisation and
saved CPX expansion has
been set; parameters and
CPX equipment status are
saved remanently; external
parameterisation is
1)
blocked
1)
Force is active
The LED M is intended for several functions (see also under
Interbus-specific LEDs). The status which is shown takes
place in the following sequence:
1. Force active
2. Parameters saved remanently
Meaning/error handling
None
Be careful when replacing
CPX valve terminals with saved
parameterisation.
With these CPX valve terminals,
parameterisation is not carried out
automatically by the higher-order
PLC/IPC when the terminal is
replaced. In these cases check before
replacing to see which settings are
required and, if necessary, carry out
these settings.
The force function is enabled
(see system parameter force mode;
function no. 4402).