7.1
Specification of Terminal X1
•
•
•
Specifications of Connecting Cable
•
•
•
•
•
Cable Shielding
•
Fig.: 7: Connection of the 3-phase supply line
Jetter AG
Description of Connections
Power Supply Connection
4-pin spring tension terminal (type ZEC 1.5/ 4-ST-7.5 C2 R1,4; for printed circuit
boards)
Diameter of the cable apt for connecting: 0.25 ... 1.5 mm
Bladed screw-driver: 0.6 x 3.5 x 100 mm
Cable size: 4 * 1.5 mm² (AWG 16(4))
Material: Copper
Temperature class: 60 °C
Stripping length of cores: 6 mm
Bootlace ferrules are not required.
Not needed
Terminals X1 on the
Amplifier Side
U1
V1
W1
PE
yellow/green
Core 3
Core 2
Core 1
X1
2
Power Supply
3-Phase Connection
Signal
L1
L2
L3
PE conductor
7.1 Power Supply Connection
2
(AWG 24 ... AWG 16)
Specification
•
AC 230 V between the
power lines
PE
Line Voltage 3
Line Voltage 2
Line Voltage 1
47