Appendix B: Differences Between Jetmove 206-230 And Jetmove 206B-230 - Jetter JM-206-230 User Manual

Digital servo amplifier
Table of Contents

Advertisement

Appendices
Appendix B: Differences between
The JetMove 206-230 servo amplifier has been developed further to become the
servo amplifier JetMove 206B-230.
The objectives of this further development have been the following:
In the development process, special attention was paid to providing a large scope of
interchangeability.
Of course, there will still remain certain differences which must be considered in
individual causes.
Automatic Encoder Recognition
The JetMove 206B-230 is not equipped with two varieties for different position
transducers any more. (Up to now, the customer had to decide whether to order the
JetMove 206-230-RE servo amplifier for the resolver input circuit or the servo
amplifier JetMove 206-230-HI for the Hiperface input circuit.)
The JetMove 206B-230 servo amplifier can automatically recognize which encoder
has been connected to it and configure its input circuit respectively.
Consequences for the user:
Enclosure
The enclosure of the servo amplifier JetMove 206B-230 has been adjusted to that of
the amplifiers JetMove 203-230-x and JetMove 215-480-x, thus emphasizing the
homogeneity of the amplifier product family.
Consequences for the user:
Installation in Control Cabinet
Thanks to the new enclosure it is now possible to fix the JetMove 206B-230 by two
screws only to the middle fixing holes in the control cabinet. The two outer mounting
hole pairs are exactly at the same position as the mounting holes of the servo
amplifier JetMove 206-203. Thus interchangeability is realized.
Consequences for the user:
108
JetMove 206-230 and JetMove
206B-230
To save components, in order to achieve greater dependability
To grant an uncomplicated installation procedure
To decrease the amount of various models
Even with both encoder types being applied, double stock-keeping can be
avoided.
Irrespective of the encoder type used, the order number is the same.
None, as the layout of the plugs, the outside measurements and the mounting
holes have remained unchanged.
The installation in the control cabinet will be simplified.