4.4

Auxiliary function transfer from NC channel

DB2500
DBX4.0 to .4
DBX6.0
DBX8.0
DBX10.0
DBX12.0 to .2
Edge evaluation: No
Signal state 1
Signal state 0
Note for the reader
DB2500
DBB1000 to DBB1012
Edge evaluation: No
Signal state 1
Signal state 0
Application
corresponding to ...
Note for the reader
DB2500
DBD2000
Edge evaluation: No
Signal state 1
Signal state 0
Application
Special cases, errors, ...
Note for the reader
Siemens Controls
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
4.4 Auxiliary function transfer from NC channel
M function Change 1 to 5
S function Change 1
T function Change 1
D function Change 1
H function Change 1 to 3
Signal(s) from channel (PLC)
Signal(s) updated: Cyclic
M, S, T, D, H information was output at the interface together with a new
value and the associated change signal. In this case, the change signal
indicates that the corresponding value is valid.
The change signals are only valid for one PLC cycle! This means that if the
signal is 1, then a change is pending for this cycle.
The value of the data involved is not valid.
Function Manual Basic Functions H2
Decoded M signals: M0 - M99
Signal(s) from channel (NCK)
Signal(s) updated: Cyclic
The dynamic M signal bits are set by decoded M functions.
For a general auxiliary function output, the dynamic M signal bits are
acknowledged by the PLC system program after the user program has
been completely run-through (executed once).
Spindle clockwise/counterclockwise rotation, switch coolant on/off
IS "M function for the spindle (DINT), axis-specific" (DB370x DBD0)
Function Manual Basic Functions H2
T function 1
Signal(s) from channel (PLC)
Signal(s) updated: job-
controlled by NCK
The T function programmed in an NC block is made available here as soon
as the T change signal is available.
Value range of the T function: 0-32000 ; integer number
The T function remains valid until it is overwritten by a new T function.
After the PLC has ramped-up.
All auxiliary functions are deleted before a new function is entered.
Control of automatic tool selection.
With T0, the actual tool is removed from the tool holder but not replaced by
a new tool (default configuration of the machine manufacturer).
Function Manual Basic Functions H2
Detailed descriptions of interface signals