11300
JOG_INC_MODE_LEVELTRIGGRD
-
INC and REF in jog mode
-
-
-
1:
Description:
JOG-INC:
When the traversing key is pressed in the required direction (e.g. +), the
axis begins to traverse the set increment. If the key is released before the
increment has been completely the traversed, the movement is interrupted and
the axis stops. If the same key is pressed again, the axis completes the
remaining distance-to-go until this is 0.
0:
JOG-INC:
When the traversing key is pressed (first rising edge) the axis travels the
whole set increment. If the same key is pressed again (second rising edge)
before the axis has completed traversing the increment, the movement is can-
celed, i.e. not completed.
The differences in axis travel behavior between the jog mode and continuous
operation in incremental traversing are described in detail in the relevant
chapters.
For travel behavior in reference point approach see
References:
MD irrelevant for:
Continuous traversing (JOG continuous)
11310
HANDWH_REVERSE
-
Threshold for direction change handwheel
-
-
-
Handwheel travel:
Description:
Value = 0:
No immediate travel in the opposite direction
Value > 0:
Immediate travel in the opposite direction if the handwheel is turned at
least the stated number of pulses in the opposite direction.
Whether this machine data is also active for handwheel travel with DRF
depends on bit10 of MD20624 $MC_HANDWH_CHAN_STOP_COND.
Siemens Controls
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
TRUE
Jog mode for JOG-INC and reference point approach
Continuous operation for JOG-INC and reference point approach
/FB/, R1, "Reference Point Approach"
2
N01
BOOLEAN
0
-
N09
BYTE
0
-
Machine data
2.2 General machine data
H1,R1
PowerOn
1/1
H1
PowerOn
2/2
65