20310
TOOL_MANAGEMENT_MASK
-
Activation of tool management functions
-
-
-
Description:
MD = 0: Tool management inactive
Bit 0 to bit4
Bit 0=1: Tool management active
Tool management functions are enabled for the current channel.
Bit 1=1: Tool monitoring function active
The functions for monitoring the tools (tool life and guantity) are enabled.
Bit 2=1: OEM functions active
The memory for user data can be used (see also MD18090
$MN_MM_NUM_CC_MAGAZINE_PARAM
to MD18098 $MN_MM_NUM_CC_MON_PARAM)
Bit 3=1: Consider adjacent location active
Bit 0 to bit 3 must be set as in MD18080 $MN_MM_TOOL_MANAGEMENT_MASK.
Bit 4=1: The PLC has the option of requesting a T preparation again with
changed parameters.
The acknowledgment states
tool selection is then recalculated in the NCK.
Bit 5 to bit 8
Bit 5 and bit 7 refer to the main spindle
Bit 6 und bit 8 refer to secondary spindles
Bit 5 = 1: The command is regarded as output when the internal transport
acknowledgment + the transport acknowledgment are present, that is, when the
command has been accepted by the basic PLC program.
(Bit 19=1 also allows the block change to be prevented (main run) until the
required acknowledgments have been received.)
Bit 7 = 1: The output of the command is not regarded as being completed until
the end acknowledgment has been received from the PLC. That is, the command
has beren acknowledged by the PLC user program with status "1".
(Bit 19=1 also allows the block change to be prevented (main run) until the
required acknowledgments have been received.)
Bit 5 and bit 7 (alternatively bit 6 and bit 8) are mutually exclusive.
Only the following combinations are permissible:
Bit 5: ...0...1...0
Bit 7: ...0...0...1
With the default setting, that is bits 5 to 8 = 0, synchronisation takes
place in the block in which a cutting edge is selected for the first time.
Setting these bits delays the block processing.
Bit 9 to bit 11
Bit 9: Reserved for test purposes
It can also be used by machine manufacturers during the test phase, provided
that the PLC program does not yet control the tool change.
Bit 10=1: M06 is delayed until the preparation has been accepted by the PLC
user program.
The change command is not output until the preparation acknowledgment has
been received. That can be, for example, status "1" or "105".
Bit 10=0: The change command is output without delay, directly after the
Siemens Controls
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
0x0, 0x0, 0x0, 0x0,
0
0x0, 0x0, 0x0, 0x0...
"2", "7" und "103" are enabled with this bit. The
2.3 Channel-specific machine data
C09
P3 pl,P3 sl
DWORD
PowerOn
0xFFFFFFF
1/1
Machine data