Siemens SINUMERIK 808D ADVANCED Operating Instructions Manual page 116

Parameter manual
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Machine data
2.3 Channel-specific machine data
20152
GCODE_RESET_MODE
-
Reset response of G groups
-
-
70
Description:
This MD is only evaluated if bit 0 is set in MD20110 $MC_RESET_MODE_MASK.
For each entry in MD20150 $MC_GCODE_RESET_VALUES (that is for each G group),
this MD is used to determine whether, on reset/part program end, the setting
in MD20150 $MC_GCODE_RESET_VALUES is used again (MD = 0) or the current set-
ting is retained (MD = 1).
Example:
Here, the basic setting for the 6th G group (current plane) is read from
MD20150 $MC_GCODE_RESET_VALUES at each reset / part program end:
MD20150 $MC_GCODE_RESET_VALUES[5]=1 ; reset value of the 6th G group is G17
MD20152 $MC_GCODE_RESET_MODE[5]=0 ; basic setting for 6th G group corre-
sponds, after; reset / part program end; to MD20150 $MC_GCODE_RESET_VALUES[5]
However, if the current setting for the 6th G group (current plane) is to be
retained after reset / part program end, then the following setting results:
MD20150 $MC_GCODE_RESET_VALUES[5]=1 ; reset value of the 6th G group is M17
MD20152 $MC_GCODE_RESET_MODE[5]=1 ; current setting for 6th G group
;is retained even after reset / part program end.
Related to:
MD20110 $MC_RESET_MODE_MASK
MD20112 $MC_START_MODE_MASK
116
0, 0, 0, 0, 0, 0, 0,
0
1...
C03
M1,K1,K2,P1
BYTE
Reset
1
1/1
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Parameter Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents