Application
corresponding to ...
Note for the reader
DB390x
DBX1.5
Edge evaluation: No
Signal state 1
Signal state 0
Application
Special cases, errors, ... The IS "Position controller active" is also set for simulation axes as soon as
corresponding to ...
Note for the reader
DB390x
DBX1.6
Edge evaluation: No
Signal state 1
Signal state 0
Application
Special cases, errors, ... The IS "Speed controller active" is also set for simulation axes, as soon as
Siemens Controls
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Enable signal for opening a protective device (e.g. "Open door").
The workpiece chuck or the tool clamping device is only opened when
the spindle is stationary.
The oscillation mode can be switched-in during gear stage change after
the spindle has been braked down to standstill.
The tool clamping device must have been closed before the spindle can
be accelerated.
MD36060 STANDSTILL_VELO_TOL
(maximum velocity / speed for signal "Axis / spindle stationary")
Function Manual Basic Functions S1
Position controller active
Signal(s) from axis / spindle (NCK → PLC)
Signal(s) updated: Cyclic
The control signals that the position controller is closed.
The control signals that the position controller is open.
If "controller enable" is withdrawn because of a fault or from the PLC user
program the position controller is opened and therefore the interface signal
"Position controller active" is set to a 0 signal.
Spindle without position control: Signal "Position controller active" is always
"0".
The IS "Position controller active" can be used as feedback signal for
the IS "Controller enable".
The holding brake of a vertical axis must be activated as soon as the
position control is no longer active.
If a spindle has been technically designed/dimensioned for the purpose,
in the part program, it can be changed-over into the closed-loop position
controlled mode as spindle or as axis (with SPCON or M70). In these
cases, the interface signal "position controller active" is set.
MD30350 = 1.
DB380x DBX2.1 (controller enable)
DB380x DBX1.5 (position measuring system 1)
MD30350 SIMU_AX_VDI_OUTPUT
(output of axis signals for simulation axes)
Function Manual Basic Functions S1
Speed controller active
Signal(s) from axis / spindle (NCK → PLC)
Signal(s) updated: Cyclic
The control signals that the speed controller is closed.
The control signals that the speed controller is open. The speed controller
output is cleared.
For spindles without closed-loop position control, the interface signal can be
used as feedback for the IS "Controller enable".
MD30350 = 1.
Detailed descriptions of interface signals
4.8 Axis / spindle-specific signals