Machine data
2.3 Channel-specific machine data
28040
MM_LUD_VALUES_MEM
-
Memory space for local user variables (DRAM)
-
-
-
This MD defines the amount of memory space available for LUD variables.
Description:
The maximum number of available LUDs is given by one of the limit values of
MD28020 $MC_MM_NUM_LUD_NAMES_TOTAL or MD28040 $MC_MM_LUD_VALUES_MEM.
The memory defined here is subdivided into (MD28040 $MC_MM_LUD_VALUES_MEM *
1024) / MD18242 $MN_MM_MAX_SIZE_OF_LUD_VALUE blocks, and allocated to part
programs which request memory. Each part program that contains at least one
definition of an LUD variable or call parameters uses at least one such
block.
It should be remembered that several part programs requiring memory can be
open simultaneously in the NCK. The number depends on the type of program-
ming, the program length, and the size of the internal NCK block memory
upwards of (MD28060 $MC_MM_IPO_BUFFER_SIZE, MD28070
$MC_MM_NUM_BLOCKS_IN_PREP).
Related to:
MD28020 $MC_MM_NUM_LUD_NAMES_TOTAL
(number of local user variables (DRAM))
28050
MM_NUM_R_PARAM
-
Number of channel-specific R variables (SRAM)
-
-
-
Defines the number of R variables available in the channel. This machine data
Description:
reserves 8 bytes of buffered user memory per R variable.
28070
MM_NUM_BLOCKS_IN_PREP
-
Number of blocks for block preparation (DRAM)
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
Defines the number of NC blocks available for NC block preparation. This fig-
Description:
ure is determined mainly by the system software and is used largely for opti-
mization. Approximately 10 Kbytes of dynamic memory is reserved per NC block.
Related to:
MD28060 $MC_MM_IPO_BUFFER_SIZE
(number of NC blocks with IPO buffer)
180
125, 125, 125, 125,
125, 125, 125,
125, 125, 125, 125...
125, 125, 125,
125, 125...
300
0
50
50
80
50
50
50
50
50
C02
V2,K1
DWORD
PowerOn
32000
1/1
C02
K1
DWORD
PowerOn
32535
1/0
EXP, C02
B1,K1
DWORD
PowerOn
500
0/0
500
1/1
500
0/0
500
0/0
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
Parameter Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents