Machine data
2.3 Channel-specific machine data
20550
EXACT_POS_MODE
-
Exact stop conditions on G00/G01.
-
-
-
Configuration of the exact stop conditions for G00 and other G codes of the
Description:
1st G code group.
The MD is decimal-coded. The units digits define the behavior at G00 (infeed
motion) and the tens digits the behavior of all the other G codes of the 1st
group ("machining G codes").
x0:
x1:
programmed exact stop condition.
x2:
the programmed exact stop condition.
x3:
programmed exact stop condition.
0x:
become active.
1x:
independent of the programmed exact stop condition.
2x:
active independent of the programmed exact stop condition.
3x:
independent of the programmed exact stop condition.
The values of the units digits and tens digits are added.
For example, the value of EXACT_POS_MODE = 2 means that the exact stop condi-
tion G602 is always activated automatically at G00, independently of which
exact stop condition was programmed. At all other G codes of group 1, the
programmed exact stop condition becomes active.
20552
EXACT_POS_MODE_G0_TO_G1
-
Exact stop condition at G00-G01 transition
-
-
-
Configuration of a stop at transition from G00 to a different G code of the
Description:
1st G code group, and also vice versa, at transition from non-G00 to G00 in
continuous-path mode.
In exact-stop mode, the positioning window programmed or set in MD20550
$MC_EXACT_POS_MODE is used.
The following applies:
0:
1:
2:
3:
4:
in addition, the override of the subsequent non-G00 block is taken into
account in the G00 block via LookAhead in the case of a change from G00 to
non-G00.
5:
in addition, the override of the subsequent block is taken into account via
LookAhead in the case of a change from G00 to non-G00 and non-G00 to G00.
138
0, 0, 0, 0, 0, 0, 0, 0...
At G00, the relevant programmed exact stop conditions become active.
At G00, G601 (fine positioning window) becomes active independent of the
At G00, G602 (coarse positioning window) becomes active independent of
At G00, G603 (setpoint value reached) becomes active independent of the
At the machining G codes, the relevant programmed exact stop conditions
At the machining G codes, G601 (fine positioning window) becomes active
At the machining G codes, G602 (coarse positioning window) becomes
At the machining G codes, G603 (setpoint value reached) becomes active
0, 0, 0, 0, 0, 0, 0, 0...
No additional stop, no control of exact stop
Behavior active as with G601 (positioning window, fine).
Behavior active as with G602 (positioning window, coarse).
Behavior active as with G603 (setpoint reached).
As 0,
As 0,
EXP
BYTE
0
33
EXP
BYTE
0
5
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
B1
NEW CONF
2/2
B1
NEW CONF
2/2