Detailed descriptions of interface signals
4.7 Channel-specific signals
Application example
Note for the reader
DB3200
DBX1.7
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
corresponding to ...
Note for the reader
DB3200
DBB2
DBX15.6 and .7
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
corresponding to ...
Note for the reader
352
This allows protection zones to be enabled:
if the actual position is within a protection zone (alarm 2 present)
if motion is to be started towards the protection zone limit (alarm 1 or 2
present)
Function Manual Basic Functions K1
Activate the program test
Signal(s) to channel (PLC → NCK)
Signal(s) updated: Cyclic
Axis disable is set internally for all axes (not spindles). Therefore the
machine axes do not move when a part program block or a part program is
being processed. The axis movements are simulated on the operator
interface with changing axis position values. The axis position values for
the display are generated from the calculated setpoints.
Otherwise, the part program is executed normally.
The part program execution is not affected by the program test function.
IS "Program test selected"
IS "Program test active"
Function Manual Basic Functions K1
Activate skip block
Signal(s) to channel (PLC → NCK)
Signal(s) updated: Cyclic
Blocks marked in the part program with a slash (/) are skipped. If there is a
series of skip blocks, this signal is only active if it is present before
decoding of the first block of the series, ideally before "NC start".
The marked part program blocks are not skipped.
IS "Skip block selected"