17950
IS_AUTOMATIC_MEM_RECONFIG
-
System: automatic memory reconfiguration
-
-
-
Value = 0 : If machine data that redefines the buffered memory is modified,
Description:
then generally the alarm 4400 is output which indicates that the user data
will be deleted the next the software is started.
Value = 1 : If machine data that redefines the buffered memory is modified,
then generally the alarm 4400 is not output. This means the data is retained
the next time the software is started.
The preassigned value is selected model-specifically and generally it must
not be changed.
17951
AUTOMATIC_MEM_RECONFIG_FILE
-
Path and file name for internal data backup
-
-
-
File name with file path where the data backup file is stored if the persis-
Description:
tent memory is reconfigured.
18030
HW_SERIAL_NUMBER
-
Hardware series number
-
-
1
During power on of the control, a unique hardware serial number is stored in
Description:
this MD:
This data cannot be written.
18040
VERSION_INFO
-
Version
-
808d-me42
5
808d-me62
5
808d-te42
5
808d-te62
5
Version identifiers of the system software
Description:
Siemens Controls
Parameter Manual
Operating Instructions, 08/2013, 6FC5397-8EP40-0BA0
FALSE
/siemens/sinumerik/
sys_cache/nck/
content.afs
For Powerline series modules this is the serial number of the NCU module
For Solutionline series modules this is the serial number of the CF card,
or the unique number of the MCI module in the case of PC-based systems
808D-ME42
808D-ME62
808D-TE42
808D-TE62
EXP, N02
BOOLEAN
-
-
EXP
STRING
-
-
N05
STRING
-
-
N05
STRING
-
-
-
-
-
-
-
-
Machine data
2.2 General machine data
-
PowerOn
1/0
-
PowerOn
1/0
-
PowerOn
ReadOnly
IAD
PowerOn
ReadOnly
ReadOnly
ReadOnly
ReadOnly