Advertisement

3. Unplug the sensor sub-cables from the power supply and from the network port, and
wait 2 seconds. (It's fine to remain attached to a GPS/IMU receiver if you have one.)
4. Reattach the sub-cable only to the power supply, and immediately start a timer.
5. Wait until the 2:45 minute mark (2 minutes and 45 seconds), when the fail safe mode
becomes enabled, allowing you 60 seconds to accomplish the next step.
NOTE: Wait time varies depending on the revision of the sensor:
6. Reattach the Ethernet sub-cable to the network port. (No additional wait time is
necessary.)
7. In the browser's URL field, type the fail safe mode URL:
192.168.1.3:7780
8. Log in with the usual case-sensitive username (
unless you updated it), as discussed on pages 42 and 53.
qeditor
9. Once you have logged in, you will need to update the sensor to a new static IP
address or change it back to a dynamically assigned IP address, as explained in the
"Edit Settings" section starting on page 44. (If you assign the sensor a new static IP
address, note it on page 40.)
10. Return your computer's network settings window to its previous configuration.

Closing the Web Server

After logging out as discussed on page 54, close the Sensor Settings Management
web server application's tab or window through mechanisms provided in your particular
browser.
Rev B: At 3:00 minute mark, an unlimited window starts.
Rev C: At 4:55 minute mark, a 10 second window starts.
Rev D: At 2:45 minute mark, a 60 second window starts.
M8 Sensor User Guide, QPN 96-00001 Rev K
) and password (which is
editor