CB-7080 & CB-7080D Counter/Timer User's Guide
Application wiring
Output drive to SSR or other load
CB-7080 and CB-7080D
11
Gate1-
12
Gate1+
In1-
13
143
In1+
15-
Gate0-
Gate0+
16
17
In0-
In0+
18
Do0/Lo
19
Do1/Hi
20
Note:
If the external load is resistive, the 1N4001 can be omitted. (transistor, lamp, resistor, etc.).
If the external load is inductive, the 1N4001 cannot be omitted. (relay coil, etc.).
Frequency Input
Use the $AABS command to select the isolated/non-isolated input.
Frequency 1
(isolated)
Frequency 0
(isolated)
GND
10
Ext. GND
+VS
9
Ext. 24V
Data+
8
RS-485 Data-
Data-
7
RS-485 Data-
Init*
6
Gate1
5
In1
4
D.Gnd
3
2
Gate0
1
In0
Figure 1-3. Output drive to SSR or other load
11
Gate1-
12
Gate1+
In1-
13
143
In1+
15-
Gate0-
Gate0+
16
17
In0-
In0+
18
Do0/Lo
19
Do1/Hi
20
CB-7080 & CB-7080D
Figure 1-4. Frequency input
1-4
External Power
External Load
1N4001
R1
+VS
+VS
SSR
R2
GND
10
Ext. GND
9
+VS
Ext. 24V
Data+
8
RS-485 Data+
Data-
7
RS-485 Data-
6
Init*
Gate1
5
Frequency-1
(non- isolated)
In1
4
D.Gnd
3
Frequency-0
2
Gate0
(non- isolated)
1
In0