Measurement Computing CB-7080 User Manual page 68

Counter/timer
Table of Contents

Advertisement

CB-7080 & CB-7080D Counter/Timer User's Guide
@AASA(data)
Description
: Set the Hi-Hi alarm limit of counter 0 (for alarm-mode 1). Refer to
selection" for more information.
Syntax
: @AASA(data)[chk](cr)
@
AA
SA
(data)
[chk]
(cr)
Response
:
Valid response
Invalid response
no response
!
?
AA
[chk]
(cr)
Examples
:
The Hi-Hi alarm limit of counter 0 is FFFF0000h:
command:
response:
The Hi-Hi alarm limit of counter 0 is 0000FFFFh:
command:
response:
A delimiter character
2-character HEX module address, from 00 to FF
8-character HEX value.
2-character checksum. If checksum is disabled, no [chk]
0x0D
!AA[chk](cr)
?AA[chk](cr)
Syntax error, communication error or address error
A delimiter character indicating a valid response
A delimiter character indicating an invalid response
2-character HEX module address
2-character checksum. If checksum is disabled, no [chk]
0x0D
@01SAFFFF0000(cr)
!01(cr)
@02SA0000FFFF(cr)
!02(cr)
2-49
@AASA(data)
"Counter alarm mode

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CB-7080 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Cb-7080d

Table of Contents