CB-7080 & CB-7080D Counter/Timer User's Guide
@AADAN
Description
: Disable alarm (for alarm-mode 0). Refer to
information.
Syntax
: @AADAN[chk](cr)
@
AA
N=0
N= 1
[chk]
(cr)
:
Response
Valid response
Invalid response
no response
!
?
AA
[chk]
(cr)
Examples
:
Disable the alarm for counter 0:
command:
response:
Disable the alarm for counter 1:
command:
response:
A delimiter character
2-character HEX module address, from 00 to FF
disable counter 0
disable counter 1
2-character checksum. If checksum is disabled
0x0D
!AA[chk](cr)
?AA[chk](cr)
Syntax error, communication error or address error
A delimiter character indicating a valid response
A delimiter character indicating an invalid response
2-character HEX module address
2-character checksum. If checksum is disabled, no [chk]
0x0D
@01DA0(cr)
!01(cr)
@02DA1(cr)
!02(cr)
"Counter alarm mode
no [chk]
2-43
@AADAN
selection" for more
Need help?
Do you have a question about the CB-7080 and is the answer not in the manual?