Aai - Measurement Computing CB-7080 User Manual

Counter/timer
Table of Contents

Advertisement

CB-7080 & CB-7080D Counter/Timer User's Guide

$AAI

Description
: Read the value of *INIT pin.
: $AAI[chk](cr)
Syntax
$
AA
I
[chk]
(cr)
Response
:
Valid response
Invalid response
no response
!
?
AA
S=0
S=1
[chk]
(cr)
Examples
:
INIT* pin is connected to GND pin:
command:
response:
INIT* pin is open:
command:
response:
Note
Refer to
"INIT*_pin operation
A delimiter character
2-character HEX module address, from 00 to FF
2-character checksum. If checksum is disabled, no [chk]
0x0D
!AAS[chk](cr)
?AA[chk](cr)
Syntax error, communication error or address error
A delimiter character indicating a valid response
A delimiter character indicating an invalid response
2-character HEX module address
INIT* pin is connected to GND pin
INIT* pin is open
2-character checksum. If checksum is disabled, no [chk]
0x0D
$01I(cr)
!010(cr)
$02I(cr)
!021(cr)
principle" for more information on INIT*.