Aa0H - Measurement Computing CB-7080 User Manual

Counter/timer
Table of Contents

Advertisement

CB-7080 & CB-7080D Counter/Timer User's Guide

$AA0H

Description:
Reads the minimum input signal width at high level. Refer to
for more information.
Syntax:
$AA0H[chk](cr)
$
AA
[chk]
(cr)
:
Response
Valid response
Invalid response
No response
!
?
AA
(data)
[chk]
(cr)
Examples
:
Min. width = 10 µs
command
response
Min. width = 1000 µs = 1 ms
command
response
A delimiter character
2-character HEX module address, from 00 to FF
2-character checksum. If checksum is disabled, no [chk].
0x0D
!AA(data)[chk](cr)
?AA[chk](cr)
Syntax error, communication error or address error
A delimiter character indicating a valid response
A delimiter character indicating an invalid response
2-character HEX module address
5-character decimal value for min. width at high level. The unit is microseconds
( s) and the range can be from 2 s to 65535 s.
2-character checksum. If checksum is disabled, no [chk].
0x0D
$010H(cr)
!0100010(cr)
$020H(cr)
!0201000(cr)
"Digital filter
2-9
$AA0H
setting" on page 1-8