CB-7080 & CB-7080D Counter/Timer User's Guide
@AAGN
Description
: Read the preset value of counter. The $AA6 command can reset counter to the preset value.
Refer to
"Preset value
setting" for more information.
Syntax
: @AAGN[chk](cr)
@
AA
G
N=0
N= 1
[chk]
(cr)
Response
:
Valid response
invalid response
no response
!
?
AA
(data)
[chk]
(cr)
:
Examples
The preset value of counter 0 is 0000FFFF:
command:
response:
The preset value of counter 1 is 00000000:
command:
response:
A delimiter character
2-character HEX module address, from 00 to FF
read counter 0
read counter 1
2-character checksum. If checksum is disabled, no [chk]
0x0D
!AA(data)[chk](cr)
?AA[chk](cr)
Syntax error, communication error or address error
A delimiter character indicating a valid response
A delimiter character indicating an invalid response
2-character HEX module address
8-character HEX value.
2-character checksum. If checksum is disabled
0x0D
@01G0(cr)
!010000FFFF(cr)
@02G1(cr)
!0200000000(cr)
no [chk]
2-44