CB-7080 & CB-7080D Counter/Timer User's Guide
@AAPA(data)
Description
: Set the Hi-alarm limit of counter 0 (for alarm mode 1). Refer to
for more information.
Syntax
: @AAPA(data)[chk](cr)
@
AA
PA
(data)
[chk]
(cr)
Response
:
Valid response
Invalid response
no response
!
?
AA
[chk]
(cr)
:
Examples
The Hi-alarm limit of counter 0 is FFFF0000h:
command:
response:
The Hi-alarm limit of counter 0 is 0000FFFFh:
command:
response:
A delimiter character
2-character HEX module address, from 00 to FF
8-character HEX value.
2-character checksum. If checksum is disabled, no [chk]
0x0D
!AA(data)[chk](cr)
?AA[chk](cr)
Syntax error, communication error or address error
A delimiter character indicating a valid response
A delimiter character indicating an invalid response
2-character HEX module address
2-character checksum. If checksum is disabled, no [chk]
0x0D
@01PAFFFF0000(cr)
!01(cr)
@02PA0000FFFF(cr)
!02(cr)
"Counter alarm mode
2-47
@AAPA(data)
selection"
Need help?