Section 9: Factory Resets
11
Press the FEED key to test print. Press the FEED key again to stop printing.
WARNING: THIS TEST ACTIVATES ALL THE HEATING ELEMENTS ON
THE PRINT HEAD AND THEREFORE SHOULD BE USED FOR TESTING
PURPOSES ONLY. FULL WIDTH LABELS MUST BE USED TO PREVENT
PRINT HEAD DAMAGE.
12
Verify that the counters on the test print have reset to 0.0 km.
13
Power Off the printer and confirm that all switches are in the Off or down position.

CLEAR HEAD COUNTERS

CAUTION: RESETTING THE PRINTER WILL CLEAR ALL REGISTERS.
1
Record all dip switch positions.
2
Place all dip switches in the Off position.
3
Place the DSW2-4 switch in the On or up position.
4
Simultaneously, press and hold the LINE and FEED keys while turning on the power switch.
5
Release the LINE and FEED keys upon hearing a beep.
LCD DISPLAY:
6
Place the DSW2-4 in the Off position.
LCD DISPLAY:
7
Press the FEED key to display the next screen.
LCD DISPLAY:
8
Press the LINE key twice to change the message from NONE to HEAD.
LCD DISPLAY:
9
Press the FEED key to clear the head counter.
LCD DISPLAY:
10
Select the print label size by pressing the LINE key.
M84Pro Service Manual
INITIALIZING ROM V00.00.00.00
MAINTENANCE MODE DIPSW2-4 ON->OFF
FACTORY MODE
COUNTER CLEAR - NONE
COUNTER CLEAR - HEAD
PRINT SIZE -
SMALL
LARGE
PN:
9001111A