SATO M84PRO Service Manual page 21

Thermal transfer printer
Hide thumbs Also See for M84PRO:
Table of Contents

Advertisement

Section 3: Interface Specifications
P
S
(DLE)
RINT
TOP
If a DLE (10 hexadecimal) is received by the printer, the print process is stopped and an ACK (06
hexadecimal) is returned if there are no errors and a NAK (16 hexadecimal) if a printer error
exists.
P
S
(DC1)
RINT
TART
If the printer has been stopped by receipt of a DLE (10 hexadecimal) command, it can be
restarted by sending a DC1 (hexadecimal 11) command. Upon receipt of this command an ACK
(06 hexadecimal) is returned if there are no errors and a NAK (16 hexadecimal) if a printer error
exists.
Note: To provide compatibility with older SATO printers, the RS232C
interface can be configured to use an earlier Bi-Com 3 ENQ/ACK/NAK
protocol selected via DSW2-8 and DSW1-7/8 (on the RS232 Interface
module).The earlier protocol did not have provisions for the Job Name
and did not respond to the DLE or DCI commands. Also, there are
additional Response Codes in the Status Byte Definition. It is
recommended that you use the current protocol rather than the earlier
version unless it is necessary for compatibility with existing software.
M84Pro Service Manual
PN 9001113A
Page 3-8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents