FACTORY RESETS
This section of the service manual covers instructions on how to return the printer to its factory
settings. The instructions are separated into differing categories of interest.
FACTORY SETTINGS / TEST PRINT
CAUTION: RESETTING THE PRINTER WILL CLEAR ALL REGISTERS.
1
Record all dip switch positions.
2
Place all dip switches in the OFF position.
3
Place the DSW2-4 in the ON position.
4
Simultaneously, press and hold the LINE and FEED keys while turning on the power switch.
5
Release the LINE and FEED keys upon hearing a beep.
LCD DISPLAY:
6
Place the DSW2-4 in the Off position.
LCD DISPLAY:
7
Press the FEED key to display the next screen.
LCD DISPLAY:
8
Press the LINE key once to change the message from NONE to ALL.
LCD DISPLAY:
9
Press the FEED key to clear the EEPROM.
LCD DISPLAY:
10
Select the print label size by pressing the LINE key.
NOTE: The default selection is large. The LINE key allows scrolling from one