Section 5: Printer Configuration
Repeat Print via External Signal (DSW3-8): Allows the applicator or other external device to
reprint the current label in the print buffer.
DSW3-8
SETTING
Off
Disabled
On
Enabled

DEFAULT SETTINGS

All switches are placed in the Off default position for shipping. This will result in the following
operating configuration:
Communications
Protocol:
Sensor
Receive Buffer
Mode
Label Sensor
Backfeed
External Signals

SOFTWARE DEFAULT SETTINGS

The printer stores the software settings upon receipt and uses them until they are again changed
by receipt of a command containing a new setting. These settings are stored in non-volatile
memory and are not affected by powering the printer off. The printer may be reset to use the
default software settings by depressing the LINE and FEED keys simultaneously while powering
the printer on. This will result in the following default configuration.
Print Darkness
Print Speed
Print Reference
Print Offset
Zero
Ignore CR/LF
Character Pitch
Auto On Line
Feed on Error
M84Pro Service Manual
DSW3
ON
OFF
DEFAULT SETTINGS
8 data bits, no parity, 1 Stop bit, 9600 Baud
SOFTWARE DEFAULT SETTINGS
6 Inches Per Second (3 for M84Pro-6)
Vertical = 0000, Horizontal = 0000
PN 9001111A
1
2
3
4
5
6
7
Ready/Busy
Gap Sensor
Multi Job
Batch/continuous
Sensor Used
Enabled
Enabled
3
+0
No Slash
Disabled
Proportional
Enabled
Enabled
8
Page 5-7