Section 8: Adjustment Procedures
4
Turn the knurled knob of sensor adjustment shaft (2) to laterally adjust sensors (3) and (4).
NOTE: Adjust sensor to align with, and register; the label hole, notch, gap, or
edge as applicable.
5
Close/install housing covers.
NOTE: Figure 10-1 in the Diagrams & Schematics section provides guidance
on housing cover installation.
EYE-MARK ON BOTTOM OF LINER
BACKING PAPER INSIDE EDGE
3MM
PRINT POSITION ADJUSTMENT
There are three methods of print position adjustment. Two of the methods allow for coarse
adjustment, and the third permits fine adjustment.
Although there are three methods, only two are recommended for non-SATO personnel. For this
reason, the VR1 potentiometer located on the main circuit board will only be identified here and
not explained.
M84Pro Service Manual
LABEL
14MM MINIMUM
LABEL
LABEL INSIDE EDGE
832
DOT COLUMN NUMBER
104MM
EYE-MARK - 7 TO 54MM ADJUSTMENT
LABEL GAP - 17 TO 64MM ADJUSTMENT
Figure 8-8, Label Stock Diagram
PN 9001111A
DIE CUT INTER-LABEL GAP 3MM NOMINAL
1
Page 8-10