Section 6: Troubleshooting
NOTE: Voltage readings must be +/- 10% of specification for proper
operation.
7 Troubleshoot and/or replace components as directed in their respective procedures.
DIAL
0 through 3 Used to determine voltage. Refer to the specifications section of this manual to determine
a component's required voltage level. Set the dial to that voltage requirement and the milli-
meter reading should be in the same range if properly performing.
4
Used for testing and adjustment of the VR5 potentiometer when Eye-Mark printing.
5
Used for testing and adjustment of the VR4 potentiometer when GAP printing.
6
Used for testing and adjustment of the VR2 potentiometer when printing with dispencer.
The potentiometer should be turned fully clock-wise for this operation.
7
Used for testing and adjustment of the VR3 potentiometer for ribbon end sensing.
M84Pro Service Manual
2
Figure 6-1, TP Test Module Usage
APPLICATION DESCRIPTION
PN 9001111A
0
1
8
2
7
5
3
6
5
4
1
3 4
0
1
8
2
7
3
6
5
4
1
6
Page 6-8