Siemens Acuson S1000 Instructions For Use Manual page 508

Diagnostic ultrasound system
Table of Contents

Advertisement

A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 9EVF4
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Focus (cm)
Res/Speed
Ensemble Size
Frequency (MHz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 9EVF4
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
F - 6 6
Operating mode: Color / Power
MI
Scan
1.34
0.70
Units
(MPa)
3.07
(mW)
32.84
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
1.40
pi,α
(cm)
(MHz)
5.24
5.15
X (cm)
1.13
Y (cm)
0.60
(µsec)
0.70
(Hz)
7.97
(MPa)
3.84
pi
(cm)
pi
(cm)
10.03
(cm)
3.00
2
(W/cm
)
368.49
2.00
10.03
5
5
12
12
5.50
5.50
Operating mode: Pulsed Doppler
MI
Scan
1.34
-
Units
(MPa)
3.07
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
1.40
pi,α
(cm)
(MHz)
5.24
-
X (cm)
-
Y (cm)
-
(µsec)
0.70
(Hz)
976.56
(MPa)
3.84
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
367.95
5.50
-
2.00
-
0.15
-
976.56
-
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
0.85
-
1.01
33.66
31.70
-
-
-
1.60
0.39
5.31
-
5.30
1.12
-
1.00
0.60
-
0.6
0.26
9.02
-
3.00
-
5.50
-
5.50
9.02
-
4.03
0.15
-
0.15
20833
-
24083
TIC
0.79
32.84
5.15
1.13
0.60
10.03
3.00
10.03
5
12
5.50
TIC
0.91
33.66
5.31
1.12
0.60
9.02
3.00
5.50
9.02
0.15
20833
I n s t r u c t i o n s f o r U s e

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acuson s2000Acuson s3000

Table of Contents