Acoustic Output Reporting Table — Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 8C3 HD
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ max. MI
pa.3
max
pa,α
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table — Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 8C3 HD
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ max. MI
pa.3
max
pa,α
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
I n s t r u c t i o n s f o r U s e
Operating mode: Pulsed Doppler
MI
Scan
1.41
Units
(MPa)
2.41
(mW)
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
3.50
pi,α
(cm)
(MHz)
2.93
X (cm)
Y (cm)
1.43
(µsec)
(Hz)
100.16
(MPa)
3.46
pi
(cm)
pi
(cm)
(cm)
2
(W/cm
)
230.88
2.85
4.50
0.15
100.06
Operating mode: M-Mode
MI
Scan
0.92
-
Units
(MPa)
1.83
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
1.20
pi,α
(cm)
(MHz)
3.93
-
X (cm)
-
Y (cm)
-
0.58
(µsec)
(Hz)
600.00
(MPa)
2.12
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
135.56
3.00
-
2.00
-
1.00
-
600.00
-
A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
0.81
-
2.23
45.44
45.44
-
-
-
1.00
0.36
3.72
-
3.72
0.24
-
0.24
1.20
-
1.20
0.34
1.00
-
6.90
-
3.75
3.75
1.00
1.00
0.10
0.10
24083
24083
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
0.20
0.39
-
15.83
11.66
2.80
2.73
2.50
0.52
-
3.68
3.41
-
2.17
1.45
-
1.20
1.20
13.07
-
20.00
-
6.90
-
3.00
3.00
-
20.00
6.00
-
1.00
1.00
-
600
600
TIC
1.89
45.44
3.72
0.24
1.20
1.00
6.90
3.75
1.00
0.10
24083
TIC
0.33
23.75
3.68
2.17
1.20
20.00
6.90
3.00
20.00
1.00
600
F - 1 9