A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e

Definitions

Symbol
FDA
IEC
MI
MI
TIS
TIS Scan
scan
TIS
TIS Non-scan
non-scan
TIB
TIB
TIC
TIC
A
A
aprt
aprt
P
p
r.3
ra
W
P
o
W
(z
)
P
(z
)
.3
1
α
s
I
(z
)
I
(z
)
TA.3
1
ta, α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z at max. I
.3max
pi,α
d
(z)
d
(z)
eq
eq
f
f
c
awf
Dim. of A
Dim. of A
aprt
aprt
PD
t
d
PRF
prr
p
@PII
p
at max. I
r
max
r
pi
d
@PII
d
at max. I
eq
max
eq
pi
FL
FL
I
@MI
at max. MI
I
PA.3
max
pa,α
Note: Pulse-average intensity (I
duration (t
).
d
F - 8
FDA
Mechanical Index
Soft Tissue Thermal Index in autoscanning mode
Soft Tissue Thermal Index in non-autoscanning mode
Bone Thermal Index
Cranial Thermal Index
Area of the active aperture
Derated peak rarefactional pressure
Ultrasonic power, except for TIS
scan
ultrasonic power passing through a one centimeter
window
Derated ultrasonic power at axial distance z
Derated spatial-peak, temporal-average intensity at axial
distance z
1
Axial distance corresponding to the location of the
2
max [min (W
(z), I
(z) x 1 cm
)], where z > z
.3
TA.3
1/2
1.69 (A
)
aprt
Axial distance at which TIB is a maximum (i.e., z
The axial distance corresponding to the maximum of the
derated spatial-peak pulse intensity integral
(megapascals).
Equivalent beam diameter as a function of axial distance
W
4
 
o
z, and is equal to
I
(z)
π
TA
the temporal-average intensity as a function of z
Center frequency
Active aperture dimensions for the azimuth and
elevational planes
Pulse duration
Pulse repetition frequency
Peak rarefactional pressure at the point where the free-
field, spatial-peak pulse intensity integral is a maximum
Equivalent beam diameter at the point where the
free-field, spatial-peak pulse intensity integral is a
maximum
Focal Length, or azimuthal and elevational lengths, if
different
Derated pulse-average intensity at the point of global
maximum reported MI
) is the ratio of the pulse-intensity integral (I
pa
Definition
Same as FDA
Same as FDA
Same as FDA
Same as FDA
Same as FDA
-12dB output beam area
Attenuated peak-rarefactional
acoustic pressure
in which case it is the
Output power
Attenuated output power at z
1
Attenuated temporal-average
intensity at z
Depth for TIS
bp
Break-point depth
= z
)
Depth for TIB
sp
B.3
Depth at the point where the
free-field, attenuated pulse intensity
integral is a maximum
Equivalent beam diameter at axial
distance z
0.5
 
where I
(z) is
TA
Acoustic working frequency
Same as FDA
Same as FDA
Pulse repetition rate
Same as FDA
Same as FDA
Same as FDA
Same as FDA
) to the pulse
pi
Units
IEC
n/a
n/a
n/a
n/a
n/a
2
cm
MPa
mW
mW
s
mW/cm
s
2
cm
cm
cm
cm
cm
MHz
cm
μs
Hz
MPa
cm
cm
2
W/cm