A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 4C1
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Focus (cm)
Frequency (MHz)
Res/Speed
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 4C1
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Focus (cm)
Frequency (MHz)
Res/Speed
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
F - 1 0
Operating mode: 2D-Mode
MI
Scan
1.29
0.29
Units
(MPa)
1.84
(mW)
132.03
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
1.60
pi,α
(cm)
(MHz)
2.05
2.03
X (cm)
4.01
Y (cm)
1.40
(µsec)
1.27
(Hz)
39.98
(MPa)
2.09
pi
(cm)
pi
(cm)
18.00
(cm)
4.88
2
(W/cm
)
101.60
2.00
18.00
2.00
2.00
3
3
Operating mode: 2D-Mode (THI)
MI
Scan
1.32
0.39
Units
(MPa)
1.84
(mW)
203.01
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
3.90
pi,α
(cm)
(MHz)
1.98
2.15
X (cm)
6.11
Y (cm)
1.40
(µsec)
0.79
(Hz)
39.97
(MPa)
2.20
pi
(cm)
pi
(cm)
18.00
(cm)
4.88
2
(W/cm
)
108.09
4.00
18.00
4.00
4.50
3
3
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIS
TIB
Non-scan
Non-scan
A
>1
A
≤1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIC
1.04
132.03
2.03
2.86
1.40
18.00
4.88
18.00
2.00
3
TIC
1.54
203.01
2.15
4.37
1.40
18.00
4.88
18.00
4.50
3
I n s t r u c t i o n s f o r U s e