Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 14L5
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 14L5 SP
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Focus (cm)
Frequency (MHz)
Res/Speed
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
I n s t r u c t i o n s f o r U s e
Operating mode: M-Mode
MI
Scan
1.22
-
Units
(MPa)
3.37
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
0.50
pi,α
(cm)
(MHz)
7.54
-
X (cm)
-
Y (cm)
-
(µsec)
0.24
(Hz)
600.00
(MPa)
3.79
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
456.68
6.00
-
0.75
-
1.0
-
600.00
-
Operating mode: 2D-Mode
MI
Scan
1.55
0.59
Units
(MPa)
4.30
(mW)
43.49
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
0.60
pi,α
(cm)
(MHz)
7.70
7.34
X (cm)
1.60
Y (cm)
0.25
(µsec)
0.25
(Hz)
43.17
(MPa)
4.70
pi
(cm)
pi
(cm)
4.00
(cm)
0.75
2
(W/cm
)
764.83
0.75
4.00
6.00
6.00
3
3
A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
0.83
-
0.83
23.92
23.92
-
-
-
7.28
-
7.28
1.51
-
1.51
0.30
-
0.30
5.26
-
1.10
-
6.00
-
6.00
5.26
-
5.26
1.00
-
1.00
600
-
600
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIC
0.79
23.92
7.28
1.51
0.30
5.26
1.10
6.00
5.26
1.00
600
TIC
1.20
43.49
7.34
1.14
0.25
4.00
0.75
4.00
6.00
3
F - 2 7