Siemens Acuson S1000 Instructions For Use Manual page 479

Diagnostic ultrasound system
Table of Contents

Advertisement

Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 4V1
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
@ max. I
P
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Focus (cm)
Res/Speed
Ensemble Size
Frequency (MHz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
Acoustic Output Reporting Table – Track 3, FDA 510(k) and IEC 60601-2-37
(Per transducer/mode that exceeds MI or TI value of 1.0)
Transducer model: 4V1
Index Label
Maximum Value
FDA
IEC
P
p
r.3
ra
W
P
o
min of [W
(z
),
Min. of [P
(z
.3
1
α
I
(z
)]
I
(z
)]
TA.3
1
ta.α
s
z
z
1
s
z
z
bp
bp
z
z
sp
b
z@PII
z @ max. I
.3max
d
(z
)
d
(z
)
eq
sp
eq
b
f
f
c
awf
Dim. of A
aprt
PD
t
d
PRF
prr
P
@ PII
P
@ max. I
r
max
r
d
@ PII
d
@ max. I
eq
max
eq
Focal Length
FLx
FLy
I
@ MI
I
@ MI max
pa.3
max
pa.3
Frequency (MHz)
Focus (cm)
Gate Size (cm)
Sample Rate (Hz)
a
This Index is not relevant to this operating mode.
b
This transducer is not intended for transcranial or neonatal cephalic uses.
c
This formulation for TIS is less than that for an alternate formulation in this mode.
#
No data is provided for this operation condition since the maximum index value is not reported for the reason listed.
I n s t r u c t i o n s f o r U s e
Operating mode: Color / Power
MI
Scan
1.18
0.88
Units
(MPa)
1.68
(mW)
114.10
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
3.70
pi,α
(cm)
(MHz)
2.03
2.04
X (cm)
1.01
Y (cm)
1.35
(µsec)
2.06
(Hz)
8.07
(MPa)
2.04
pi
(cm)
pi
(cm)
4.02
(cm)
7.00
2
(W/cm
)
102.39
4.02
4.02
5
5
12
12
2.00
2.75
Operating mode: Pulsed Doppler
MI
Scan
1.29
-
Units
(MPa)
1.85
(mW)
-
),
(mW)
s
(cm)
(cm)
(cm)
(cm)
4.20
pi,α
(cm)
(MHz)
2.05
-
X (cm)
-
Y (cm)
-
(µsec)
2.64
(Hz)
610.35
(MPa)
2.44
pi
(cm)
pi
(cm)
-
(cm)
-
2
(W/cm
)
130.54
2.00
-
5.01
-
0.40
-
610.35
-
A p p e n d i x F A c o u s t i c O u t p u t R e f e r e n c e
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TIS
TIB
Non-scan
Non-scan
A
≤1
A
>1
aprt
aprt
-
1.44
3.76
-
297.14
146.73
4.6
3.11
7.90
0.58
-
2.05
2.05
-
2.51
2.51
-
1.35
1.35
0.54
-
10.03
-
7.00
-
2.00
2.00
-
10.03
10.03
-
0.40
0.40
-
26042
26042
TIC
3.27
281.64
2.04
2.82
1.35
29.41
7.00
29.41
5
12
2.00
TIC
3.65
320.88
2.05
2.82
1.35
12.03
7.00
2.00
12.03
0.40
22321
F - 3 7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acuson s2000Acuson s3000

Table of Contents