4
Mounting
4.2.4
Profile mountings
The minimum number of profile mountings to be used is dependent on the stroke of the X-axis and the
mounting position.
Stroke of the X-axis
500 mm
500 mm
Tab. 4.1
Mounting examples (top view)
Horizontal mounting position (< 500 mm)
2 profile mountings per profile at the profile ends,
optionally inside or outside
Horizontal mounting position ( 500 mm)
2 profile mountings per profile at the profile ends,
optionally inside or outside
1 additional profile mounting per profile in the
middle
14
Minimum number of profile mountings
Horizontal mounting position
2 per profile, inside or outside
3 per profile, inside or outside
Mounting position not horizontal (< 500 mm)
4 profile mountings per profile at the profile ends,
in each case inside and outside
Mounting position not horizontal ( 500 mm)
4 profile mountings per profile at the profile ends,
in each case inside and outside, 2 additional pro
file mountings per profile in the middle
Mounting position not horizontal
4 per profile, inside and outside
6 per profile, inside and outside
Festo – EXCM-30-EN – 1605b – English