11) FC optical adapter with a dust cap ............................................1 pc;
12) SC optical adapter with a dust cap............................................1 pc;
13) USB port cable ..........................................................................1 pc;
14) Calibration certificate.................................................................1 pc;
15) Quick start guide .......................................................................1 pc.

2.4. Specifications

2.4.1. Spectrum Analyzer

Operating frequency range:
- terrestrial broadcasting mode: ....................................................................5 to 1200 MHz;
- satellite broadcasting mode: ...................................................................950 to 2150 MHz;
Frequency resolution: ................................................................................................25 kHz;
Level measurement range:.......................................................................... 20 to 120 dBμV;
Level measurement accuracy: ..................................................................................±1.2 dB;
Level measurement accuracy at operating temperature: ..........................................±1.5 dB;
Level measurement resolution:.................................................................................. 0.1 dB;
Frequency indication: ........................................................................................ 7 characters;
Channel number indication: .............................................................................. 3 characters;
Signal level indication: ...................................................................................... 4 characters;
Frequency sweep range: .......................................... 10,20,50,100,200,400,800,1200 MHz;
Measurement detector: .......................................................Quasi-peak, Root-mean-square;
Reference level:....................................................................... 50 to 120 dBμV, 10 dB step;
Resolution bandwidths:.................................................................... 50, 120, 250, 1000 kHz;
Number of markers: ............................................................................................................2;
"Quick" frequency sweep time in frequency ranges, less than:
- 1200 MHz: .............................................................................................................. 250 ms;
- 800 MHz: ................................................................................................................ 170 ms;
- 10,20,50,100,200 MHz: ........................................................................................... 70 ms.

2.4.2. Analog TV signal parameters measurement

Operating frequency range: .........................................................................42 to 1002 MHz;
TV broadcasting standards: ........................................................................ B/G, I, D/K, M/N;
Color TV broadcasting standards: .......................................................PAL, SECAM, NTSC;
Level measurement range:........................................................................... 30 to 120 dBμV;
Level measurement accuracy (C/N>20 dB): .............................................................±1.2 dB;
Level measurement resolution:.................................................................................. 0.1 dB;
Upper C/N measurement range value (channel level > 65 dBμV): ............................. 50 dB;
HUM measurement range:.................................................................................. 0.6 to 20%;
Lower CSO/CTB measurement range value (channel level > 65 dBμV): ................ -62 dBc;

2.4.3. Digital CATV signal parameters measurement

Operating frequency range: .........................................................................42 to 1002 MHz;
Power measurement range: ........................................................................ 35 to 115 dBμV;
Power measurement accuracy (C/N>20 dB): ...........................................................±1.2 dB;
Digital CATV standards:............................................................... ITU-T J.83 ANNEX A/B/C;
Modulation type: .......................................................................QAM64, QAM128, QAM256;
Symbol rate:.................................................................................................5.0 to 7.2 MSps;
MER measurement range:................................................................................. 29 to 42 dB;
MER measurement accuracy:...................................................................................±2.0 dB;
MER measurement resolution: .................................................................................. 0.1 dB;
BER measurement resolution: ............................................................. 1.0x10
8
-3
-12
to 1.0x10
;