Diseqc Control Mode - Planar IT-100 Operating Manual

Multisystem tv analyzer
Table of Contents

Advertisement

− TP:
setting
− LNB band: LO operating ranges displayed on the horizontal scale.
8) Level scale.
9) Motor control. Enabling or disabling DiSEqC positioner operating mode
(section 4.4.7).
To switch the LNB power supply on and off, use the source control mode. To call the
mode, press the «Shift» key and then, without releasing it, press
(section 4.3.1.5).
LNB converter configuring is performed in the F2 / LNB popup menu (section
4.4.14.4.2).
To open the Channel, MER/BER or DiSEqC measurement modes, use the F3, F4
and F5 keys in the additional set of functions which is started by the Shift key.

4.4.6. DiSEqC control mode

The
icon in the main selection menu corresponds to this mode. The mode is
intended for sending arbitrary DiSEqC commands. The Analyzer serves as a master
DiSEqC device in this mode. The mode screen view is presented in fig. 4.35.
The mode features a table of sent commands and responses to them as a sequence
of bite in hexadecimal format. The last sent commands are indicated in the beginning of
the list.
To send a typical command, press the F1 / List key and select one of the commands
from the dropdown menu:
1) 1.0 Switch. DiSEqC 1.0 switch control command. You need to specify the input
number (1...4);
2) 1.1 Switch. DiSEqC 1.1 switch control command. You need to specify the input
number (1...16);
3) SCR LNB UB signal on. The command switches the tone on in all SCR LNB
slots;
4) SCR LNB UB power off. The command switches the tone off in the given SCR
LNB slot. You need to specify the slot number;
5) Stop. The command enables positioner movement stopping;
6) Go home. The command enables positioner moving to the starting position;
7) Go to position. The command enables positioner moving to the given position.
You need to specify the position number (1...99);
8) Save position. The command enables position saving under the given number.
You need to specify the position number (1...99).
Transponders bandwidth displayed on the horizontal scale. The
is available only if the converter profile is selected.
Setting the amplitude scale value: 5, 10 dB.
Figure 4.35
49