2) Max PMT interval, ms. The maximum repetition period of all sections of the PMT
table: 1...60000 ms;
3) Max Video/Audio interval, ms. The maximum repetition period of video and
audio elementary streams packets: 1...60000 ms;
4) Max user PID interval, ms. The maximum repetition period of the data
elementary streams: 1...60000 ms;
5) Max PCR interval, ms. The maximum repetition period of PCR timestamps for
each of the program: 1...60000 ms;
6) Max PCR delta value, ms. The maximum difference between the two
consecutive PCR timestamps counter values (PCR
program: 1...60000 ms;
7) Max PCR accuracy error, ns. The maximum allowed value of the PCR accuracy
metric (absolute value) for each of the program: 1...60000 ns;
8) Max PCR frequency offset, Hz. The maximum allowed value of the PCR
timestamps frequency offset (absolute value) for each of the program: 1...60000
Hz;
9) Max PCR drift rate, mHz/s. Maximum allowed value of the of PCR timestamps
frequency drift rate (absolute value) for each of the program: 1...60000 mHz/s;
10) Max PTS interval, ms. The maximum allowed repetition period of the PTS
timestamps for each of the elementary stream: 1...4000 ms;
11) Max NIT act./oth. interval, ms. The maximum repetition period of all sections of
the NIT table for each broadcast networks: 1...60000 ms;
12) Max CAT interval, ms. The maximum repetition period of all sections of the CAT
table: 1...60000 ms;
13) Max BAT interval, ms. The maximum repetition period of all sections of the BAT
table for each of the bouquet: 1...60000 ms;
14) Min section interval, ms. The minimum allowed time between arrival of any two
sections of the same table: 1...16000 ms;
15) Unreferenced PID duration, ms. Maximum allowed time during which a PID
doesn't referenced by PSI/SI tables: 1...60000 ms;
16) Max SDT actual interval, ms. The maximum repetition period of all sections of
the SDT table of the current transport stream: 1...60000 ms;
17) Max SDT other interval, ms. The maximum repetition period of all sections of the
SDT table for each of the transport streams different from the current one:
1...60000 ms;
18) Max EIT P/F actual interval, ms. The maximum repetition period of all sections
of the EIT table (current/following event) for each program of the current transport
stream: 1...3000 ms;
19) Max EIT P/F other interval, ms. The maximum repetition period of all sections of
the EIT table (current/following event) for each program of transport streams
different from the current one: 1...60000 ms;
20) Max TDT/TOT interval, ms. The maximum repetition period of all sections of the
TOT and TDT tables: 1...32500 ms;
The cursor is moved by using the «◄», «►», « » and « » buttons. The value for
the parameter at the cursor position can be edited by using the alpha-numeric keyboard.
To set the default limit values for the current profile, press the «F2 / Default» button.
To exit from the mode with saving of changes it is necessary to press the «F1 /
Save» button. To exit and discard changes, press the «EXIT» button.
4.6.3.3. Transport stream objects exception from analysis setting
Setting the exception of the transport stream objects from the analysis is performed
by using the table, as shown in the figure 4.52.
i
69
– PCR
) for each of the