This Operating Manual is made in accordance with CIU-003 firmware version 14.0.0.7
and ViewRSA software version 2.1.9.
1.4. Environmental Conditions
Normal operating conditions:
a) ambient temperature 23±5
b) relative air humidity 55±25%;
c)
atmospheric pressure 84-106 kPa (630-795 mm Hg);
d) voltage transients in compliance with installation category CAT. II.
Rated operating conditions:
а) ambient temperature +10 to +40 °С;
b) relative air humidity not more than 80% at 25 ºС;
c)
atmospheric pressure 84-106 kPa (630-795 mm Hg).
1.5. Package Contents
The Analyzer package includes:
a) CIU-003 Analyzer .................................1 pc.
b) Power Supply Cord with Europlug ........1 pc.
c)
COM Port Data Transfer Cable ............1 pc.
d) CD with Software ..................................1 pc.
e) Rubber mounts .....................................4 pc.
f)
Operating Manual .................................1 pc.
1.6. Specifications
Input parameters:
a) Input impedance within operating frequency range:
b) Allowed resulting value of AC input voltage:
Operating frequency range
Resolution
Built-in attenuator
Level measurement mode:
- Input attenuator off
- 20 dB input attenuator
- 40 dB input attenuator
Level measurement resolution
Accuracy within 30-120 dBµV level range
Accuracy at operating temperature
Measurement channel passband for -3 dB level
DVB-C demodulator parameters:
- Supported modulation types
- Supported symbol rate
MER measurement range:
- QAM64
- QAM256
MER measurement resolution
MER measurement accuracy (DVB-C channel power level no less
than 60 dBμV)
BER measurement range:
- BER before Reed-Solomon decoder
0
С;
DVB-C
7
75 Ohm
2 V
48 to 1000 MHz
125 kHz
20 dB, 40 dB
30 to 80 dBμV
50 to 100 dBμV
70 to 120 dBμV
0.1 dB
±1.5 dB
±2.2 dB
230 ± 60 kHz
QAM64, QAM128,
QAM256
5000 to 7000 Msps
22 to 42 dB
28 to 42 dB
0.1 dB
±2.0 dB
-3
5.0x10
to 1.0x10
-9