Transport Stream Analysis Profile Settings - Planar IT-100 Operating Manual

Multisystem tv analyzer
Table of Contents

Advertisement

3) Beep on event. Switching on/off sound signal playing in case an event occurs
during the TS analysis;
4) Autosave. Switching automatic analysis results saving to a file upon analysis
completion: Off, On.
Configuring of the analysis profile settings is performed in the "F2 / Profile" button
context menu. The menu contains the following options (section 4.6.3):
1) TR101290. Selecting ETSI TR 101290 parameters to be checked during the
analysis;
2) Limits. Setting the limit values for the TS parameters (repetition rate of PSI/SI
tables, PTS timestamps, PCR timestamps, etc.);
3) Exceptions. Excepting some TS objects from the analysis. This can be useful
when the analyzed TS has a complex structure, in case the Analyzer doesn't have
enough resources to handle such TS.
The analysis is started by pressing the «F5 / Start» button. In case the Autosave
function is switched on, it is necessary to specify the page name for further automatic
saving to a file. Pressing the «F6 / Stop» button again leads to the analysis stopping.
Access to the analysis measurement results is available from the «F3 / Results»
button context menu. One of the following items can be selected:
1) Events. Enter to the analysis events logger (section 4.6.5);
2) Errors. Enter to the analysis errors detailed information window for each of the
ETSI TR 101 290 priorities (section 4.6.6).
Press «F4 / Stream» button to learn the TS structure. Select one of the following
items in the appeared context menu:
1) Services. Enter to the TS programs list (section 4.6.7);
2) PIDs. Enter to the TS PIDs list (section 4.6.9);
3) PSI/SI. Enter to the TS service information tables tree view (section 4.6.10).
Analysis results can be saved to a file upon completion or forced stop of
measurement by pressing the «F6 / Save» key. Specify the page name in the popup field
and press «ENTER». In case a USB flash drive is connected to the Analyzer, the page will
be saved to it, otherwise the page will be saved to the internal drive. You can view the
analysis results saved to a file in the file manager (section 4.9), by selecting the «MPEG
analysis results» file type.
Press the «EXIT» button to leave the TS analysis mode. In order to prevent
accidental data loss, the Analyzer cannot be switched off during the analysis.

4.6.3. Transport stream analysis profile settings

Access to the
information window (section 4.6.2) from «F2 / Profile» button context menu. The active
profile can be selected in the TS analysis settings context menu.
4.6.3.1. ETSI TR 101 290 parameters checking list
Selecting ETSI TR 101 290 parameters to be checked during the analysis is
performed from the list, as shown in the figure 4.50.
TS analysis profile settings is performed from the TS general
65