5) Unexpected PSI/SI count. The number of detected service information tables
(PSI/SI) that should not appear in this PID. If the value is more than 0, it is
displayed on a red background;
6) PID interval. The indicator of elementary stream repetition period exceeding the
defined limit: OK – no errors detected, ERROR – one or more errors are detected
(displayed on the red background);
7) Reference to PID. The indicator of the lack of reference to PID in the service
information tables (PSI/SI) of the transport stream. The parameter is displayed
only for PID without the reference and «not found» value is displayed on the red
background.
A list of the objects transmitted in the selected PID is displayed at the bottom of the
table («Contents» group):
1) the service information table (PSI/SI), as part of: PAT, CAT, PMT, NIT (the NIT
for the current network broadcast), NIT-oth (NIT for the broadcast networks
different from the current one), SDT (SDT for the current transport stream) SDT-
oth (SDT for transport streams different from the current one), EIT
(current/following event for the programs of the current transport stream) EIT-oth
(present/following event for the programs of the transport streams different from
the current one), EIT-sch (schedule for a few days for the programs of the current
transport streams), EIT-oth-sch (schedule for a few days for programs transport
streams different from the current one), BAT, TOT, TDT, ST, RST, TSDT;
2) VID. Video elementary stream;
3) AUD. Audio elementary stream;
4) DAT. Data elementary stream;
5) ECM. The messages stream of access control: information about the rules of
access to the channels and bouquets of the channels;
6) EMM. The messages stream of access management: information about the
authorization of subscribers and groups of subscribers, the cryptographic keys;
7) NULL. Staffing, transmitted in PID=0x1FFF.
Below the content description group, there is a field with the name of the program
that contains the selected PID, or the name of the program that references to the selected
PID. In case the several programs reference to the selected PID, the number of programs
is displayed instead of the program name.
If the object transmitting in the PID contains errors, its name is displayed on a red
background.
The cursor move through the PIDs which contain errors is performed by pressing the
«F1 / ◄Error» and «F6 / Error►» button. For the convenience of data analysis, it is
possible to display a PIDs list that is matched to the filter specified by the «F2 / Filter»
button context menu:
1) All. Display all the PIDs;
2) Erroneous. Display only the PIDs that contains the errors;
3) EMM/ECM. Display only EMM and ECM PIDs;
4) ES. Display only the elementary stream PIDs;
5) PSI/SI. Display only PIDs with the service information tables.
For elementary stream PIDs pressing the «F3 / Service» button leads to switching to
the programs list view with setting the cursor on the program the selected PID refer to.
By pressing the «F4 / Content» button, the context menu will appear that allows to
switch to one of the following modes:
1) For elementary streams (VID, AUD, DAT). Go to the program detailed information
view (section 4.6.7) with setting the cursor on the selected elementary stream;