7.10 SETUP A STEERING DEVICE

When an additional sensor/steering device has been mapped, make sure that all common parameter are setup
accordingly, e.g. if a redundant WAS is mapped (P3245 set to 255), the following parameters needs to checked and
configured:
Name
Redundant analogue
P3211
U16
sensor max left position
Redundant analogue
sensor max right
P3213
U16
position
Redundant analogue
P3215
U16
sensor neutral position
5V sensor supply for
redundant analogue
P3219
U16
sensor during calibration
Voltage compensation
for Redundant analogue
P3247
U8
sensor
Additionally, any additional applied sensors also needs to be calibrated.
For more detailed description on how to setup sensors and steering devices and changing parameters, please see the
Danfoss documents, PVED-CLS Communication Protocol and PVED-CLS KWP2000 Protocol.

External sensors

For being able to start up the PVED-CLS in operational mode/off-road steering mode, the below mentioned sensors can
be connected to the PVED-CLS before start-up and the WAS and spool dead-bands must be calibrated. If WAS and SASA
© Danfoss | August 2018
Description of parameter
mVolts
Redundant analogue sensor voltage output for leftmost position
mVolts
Redundant analogue sensor voltage output for rightmost position
mVolts
Redundant analogue sensor voltage output for neutral position
Measured Supply voltage during calibration of the redundant analogue
mVolts
sensor
Supply voltage compensation Enable/Disable for processing redundant
-
analogue sensor signal
Valid Values: 0 (DISABLE); 255 (ENABLE)
Table 21
Range
OEM
0
6000
OEM
0
6000
OEM
0
6000
OEM
4650
5350
OEM
0
255
AQ00000211 | 51
500
4500
2500
5000
255