Case controller, type EKC 223 and EKC 224
Figure 21: SET button parameter list
SET button
SET
3 s: configuration settings
Set
(PS)
V
PS: Access code (if any)
in
cFg
Set
r12
V
o61
r--
o06
A--
o02
d--
o37
F--
o62
c--
o03
o--
P--
(Return)
u--
<
(Return)
Quick setup – get a good start
With the following procedure you can start regulation very quickly:
1.
Press the "SET" button for 3 seconds and access the parameter menu (display will show "cFg").
2.
Press the down button "∨" to go to "cFg" menu (display will show "cFg")
3.
Press the right ">" key to open the configuration menu (display will show r12).
4.
Open the "r12 Main switch" parameter and stop control by setting it OFF (Press SET).
5.
Open the "o61 application mode" and select the needed application mode (Press SET).
6.
Open the "o06 Sensor type" and select the temperature sensor type used (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC,
Pt1=Pt1000) – (Press "SET").
7.
Open the "o02 DI1 Configuration" and select the function associated to digital input 1 (see
configuration) – (Press "SET").
8.
Open the "o37 DI2 Configuration" and select the function associated to digital input 2 (see
configuration) – (Press "SET").
9.
Open the "o62 Quick setting" parameter and select the presetting that fits with the application in use (see
11: Quick
setting) – (Press "SET").
10.
Open the "o03 Network address" and set the Modbus address if required
11.
Navigate back to parameter "r12 Main switch" and set it in "ON" position to start control.
12.
Go through the entire parameter list and change the factory settings where needed.
Table 11: Quick setting
Parameter
1
Cabinet MT
Natural def.
Stop on time
r00 Cut-out
4 °C
r02 Max Cut-out
6 °C
r03 Min Cut-out
2 °C
A13 HighLim Air
10 °C
A14 LowLim Air
-5 °C
d01 Def. Method
Natural
d03 Def.Interval
6 hour
d10 DefStopSens.
Time
o02 DI1 Config.
© Danfoss | Climate Solutions | 2023.05
Main switch
Application mode
Temperature sensor type
DI1 Configuration
DI2 Configuration
Quick setup
Network address
<
2
Cabinet MT
Cabinet MT
El. def.
Stop on time
Stop on temp
2 °C
4 °C
0 °C
8 °C
-5 °C
Electrical
Electrical
6 hour
Time
S5 Sensor
3
4
Cabinet LT
El. def.
El. def.
Stop on temp
2 °C
-24 °C
4 °C
-22 °C
0 °C
-26 °C
8 °C
-15 °C
-5 °C
-30 °C
Electrical
6 hour
12 hour
S5 Sensor
DI input
DI input
5
6
Room MT
Room MT
El. def.
El. def.
Stop on time
Stop on temp
6 °C
3 °C
8 °C
5 °C
4 °C
1 °C
10 °C
8 °C
0 °C
0 °C
Electrical
Electrical
8 hour
8 hour
Time
S5 Sensor
Door fct.
Door fct.
BC432222569027en-000201 | 22
Table
7
Room LT
El. def.
Stop on temp
-22 °C
-20 °C
-24 °C
-15 °C
-30 °C
Electrical
12 hour
S5 Sensor
Door fct.
Need help?