PVED-CLS LED DIAGNOSTIC

The PVED-CLS is equipped with a LED (see Figure 12). The LED behavior will inform about the state of the PVED-
CLS:
State
Main µC in the bootloader mode
or Main µC detects the Safety µC in the bootloader mode
PVED-CLS is performing the initialization
or is in the on-road mode (electro-hydraulic steering disabled)
PVED-CLS is in the Safe State and information about the detected failure is
available on CAN bus
PVED-CLS is in the off-road steering mode (steering wheel, auto-guidance or
other program) and the spool is in its neutral position
or PVED-CLS is in the service mode
The coils supply switch is turned on and the spool is outside its dead-band
PVED-CLS is in the Safe State, but no information about the detected failure is
available on CAN bus (e.g. the address arbitration has been lost or the Main µC
built-in CAN controller failed to initialize or is unable to recover from the bus-off
situation)
For more information regarding technical specification, please see Danfoss Document, PVED-CLS Technical
Information.
© Danfoss | August 2018
Table 4
Figure 12
LED behavior
Blinking between
orange and green
Orange
Blinking orange
Green
Blinking green
Red
AQ00000211 | 31