11.12.4 Elobau Joystick - Parameter Configuration - Danfoss PVED-CLS User Manual

Controller for electrohydraulic steering
Hide thumbs Also See for PVED-CLS:
Table of Contents

Advertisement

ENGINEERING TOMORROW

11.12.4 Elobau Joystick - Parameter Configuration

Name
AUX present
P3239
U8
AUX type
P3240
U8
PGN for AUX Elobau
P3329
U16
joystick
AUX device (joystick)
P3300
U8
source address
AUX joystick in use -
Flow command
P3647
U8
threshold
Important
The PVED-CLS will only handle byte 1 and 2 of BJM and EJM messages received from ELOBAU joystick, all other bytes
are treated as "don't cares" by the PVED-CLS and no checks will be performed on these.
Important
Danfoss PVED-CLS is not handling DM1 message send by the ELOBAU Joystick as this is not relevant for steering
applications.
118 | © Danfoss | August 2018
Description of parameter
AUX device Present/Not Present
-
Valid Values: 0 (NOT PRESENT); 255 (PRESENT)
Aux device is mini steering wheel or Joystick
-
Valid Values: 0 (Open Loop Joystick); 1 (Closed Loop Joystick); 2 (mini
steering wheel); 3 (Analogue Joystick);20 (Elobau joystick)
PGN for Aux Elobau Joystick-
-
PGN' values for BJM1,BJM2,EJM1 and EJM2 are 64982,64984,64983 and
64985 respectively.
-
J1939 Source Address of the AUX device (joystick)
IR
AUX Joystick flow command threshold to declare that joystick is in use
Table 52
Range
OEM
0
255
OEM
0
20
OEM
0
65535
OEM
0
253
OEM
0
100
AQ00000211
0
2
64982
78
10
S