Glass Doors And Folding Doors - Siemens SIDOOR AT40 System Manual

Automatic door control
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

SIDOOR functions
3.3 Extended functions
3.3.3

Glass doors and folding doors

Description of function
According to DIN EN81-20, the opening force for glass and folding doors must be limited to
150 N and a function must be provided for stopping in the event of hands being pulled in.
Parameter assignment
Opening force 150 N:
The "Static opening force" parameter can be set to a value of 150 N, taking the
counterweight into account, by means of the service menu "
Opening force 150 N
After selecting this menu item, a counterweight (m) can be set in the range of 0 to 8 kg. The
resulting opening force (F) is calculated on the basis of the set counterweight:
This allows an opening force in the range of 150 N to 230 N to be set.
If the set opening force is outside this range, "
the service menu.
Stopping in case where hands are pulled in:
Via the service menu "
of opening attempts can be set when an obstruction is detected in the opening direction.
The default value is 3 opening attempts. If the value 0 is set, the door stops after an
obstruction and no opening attempts are made.
NOTICE
For glass and folding doors, the force in the opening direction must be set to 150 N +
counterweight. When commissioning the door, make sure that an opening force of 150 N is
not exceeded. Set the number of opening attempts to 0.
42
".
Quick setup > Reversing behavior > Opening attempts
Quick setup > Glass doors >
Opening force 150 N Inactive
Door control units SIDOOR AT40 and ATD400V for elevators
System Manual, 06/2018, A5E42192709-AC
" is displayed in
", the number