Adjustment ranges
The parameter can be adjusted in accordance with the adjustment ranges of the parameters
(see section Profiles and adjustment ranges (Page 136)). The value of the parameter must
be selected so that the force end counter opposing the door is overcome, and the door is
closed completely.
Static force limit open
This force is in effect during the opening movement if an open command is set.
Figure 4-6
Adjustment ranges
The parameter can be adjusted in accordance with the adjustment ranges of the parameters
(see section Profiles and adjustment ranges (Page 136)). The value of the parameter must
be selected so that the door moves across the entire door width in the opening direction if an
open command is set. Inadequate force can lead to an obstruction of the door.
Danger of injury and damage to property through excessive opening force of the door.
Limit the opening force of glass and folding doors to 150 N.
See section Glass leaf and folding leaf doors (Page 42).
Door control units SIDOOR AT40 and ATD400V for elevators
System Manual, 06/2018, A5E42192709-AC
Current – force – motor characteristic in opening direction
WARNING
4.7 Operating and parameterizing controllers
Controllers
79