4.4

Connecting terminals

4.4.1

Digital input signals

Slots X6 and X5
You can connect certain signals for drive functions at the inputs X3, X5, X6 and X7. The
following table shows how the drive function and input are assigned depending on the
control device.
Table 4- 2
Slots X6 and X5
X6 Pin6 (Inp1)
X6 Pin5 (Inp1)
X6 Pin4 (Inp2-4)
X6 Pin3 (Inp2)
X6 Pin2 (Inp3)
X6 Pin1 (Inp4)
X5 Pin1 (Inp0)
X5 Pin2 (Inp0)
Adjustable via the service menu "General setup > Special parameters > Input X5".
1)
Adjustable via the service menu "General setup > Special parameters > Input 1"
2)
Note
If Input 1 is set as the light barrier input (default setting) and no light barrier is connected, X6
must be jumpered with X4 according to the connection diagrams (see following table "Wiring
diagrams for digital input signals").
Note
Input 1 (see section (Page 58), LED signals table) is isolated from input 0, input 2, input 3
and input 4. Therefore, input X6 Pin 2 can be connected independent of inputs X6 Pin 1, 3,
4, 5 and 6 and X5 as follows:
1. Connection to the internal 24 V control voltage (see figure c below.)
2. Connection to the same or a different external control voltage as input 0, input 2, input 3
and input 4 (see figures b and d below.)
Door control units SIDOOR AT40 and ATD400V for elevators
System Manual, 06/2018, A5E42192709-AC
Overview of signals for drive functions at slots X6 and X5
AT40 / ATD400V
Light barrier/DCPS -
2)
Light barrier/DCPS +
2)
GND
Nudge
CLOSE
OPEN
Emergency power mode / FC light barrier +
1)
Emergency power mode / FC light barrier -
1)
Controllers
4.4 Connecting terminals
51