SIDOOR functions
3.1 Basic functions
3.1.4

DOOR CLOSE (command given via digital inputs)

Description of function
The DOOR CLOSE command closes the door according to the set driving curve as long as
the command is present. The door reaches the CLOSED position at slow end speed close.
In the area of the slow start and end distances, the force is limited to the configured limit
force. Then the door is kept closed for 2 seconds with the "Peak torque close" parameter
and then with the "Idle torque close" parameter.
Note
If the commands DOOR CLOSE and DOOR OPEN are present simultaneously, the door
always moves in the OPEN direction. The DOOR OPEN command takes the highest priority
against all other control commands.
Connection
The "DOOR CLOSE" function is connected to the input terminal X6 Pin 2. See also Section
Digital input signals (Page 51).
Signals
Signal
1 (voltage applied)
0 (voltage not applied)
3.1.5

DOOR OPEN (command given via digital inputs)

Description of function
The DOOR OPEN command opens the door according to the set driving curve as long as
the command is present. The door reaches the OPEN position at creep speed. Then, if the
DOOR OPEN command is present, the door is held open by the torque that can be adjusted
by the parameter "Continuous torque OPEN".
The DOOR OPEN command has priority over all other control commands.
Exceptions:
Note
If the commands DOOR CLOSE and DOOR OPEN are present simultaneously, the door
always moves in the OPEN direction.
26
Description
The DOOR CLOSE command is present
The DOOR CLOSE command is not present
Door control units SIDOOR AT40 and ATD400V for elevators