Sidoor M4 Adjustment Ranges - Siemens SIDOOR AT40 System Manual

Automatic door control
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

A.1.4.3

SIDOOR M4 adjustment ranges

Table A- 7
Parameter
Slow start distance open
Slow start distance open
Slow start distance close
Slow end distance close
Maximum speed open
Slow end speed open
Slow start speed open
Slow initial speed open
Maximum speed close
Slow start speed close
Slow end speed close
Slow initial speed close
Nudging speed close
Acceleration ramp open
Deceleration ramp open
Reversal ramp open/close
Acceleration ramp close
Deceleration ramp close
Reversal ramp close/open
Idle torque open
Idle torque close
Peak torque close
Limit force open static
Static closing force
Limit force end close
Force close nudging
Door control units SIDOOR AT40 and ATD400V for elevators
System Manual, 06/2018, A5E42192709-AC
SIDOOR M4 L / R adjustment ranges
A.1 Profiles and adjustment ranges
Unit
Adjustment range
AT40
mm
0 ... 100
mm
0 ... 150
mm
0 ... 100
mm
0 ... 150
mm/s
100 ... 750
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
100 ... 500
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
50 ... 250
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
mm/s
300 ... 1400
2
A
0 ... 2.5
A
0 ... 2.5
A
0 ... 5
N
70 ... 360
N
70 ... 230
N
70 ... 230
N
70 ... 230
Appendixes
ATD400V
0 ... 100
0 ... 100
0 ... 100
0 ... 100
100 ... 750
30 ... 90
30 ... 90
30 ... 90
100 ... 300
30 ... 90
30 ... 90
30 ... 90
50 ... 250
300 ... 1400
300 ... 1400
300 ... 1400
300 ... 1400
300 ... 1400
300 ... 1400
0 ... 2.5
0 ... 2.5
0 ... 5
70 ... 360
70 ... 230
70 ... 230
70 ... 230
143